TTR Test Set
ZC-203A Full automatic TTR Test Set Brief Introduction
According to the relevant provisions of the state and IEC, in power transformer production, in the process of user handover and maintenance test that the transformer test must be done, so it can be used for quality supervision of transformer, to prevent the transformer inter-turn short circuit, open circuit, connection error, voltage regulating switch internal fault or contact failure. we develop the production of ZC-203A automatic ratio tester according to the user's requirements on-site using, make the operation more convenient, complete functions, reliable data, test speed is greatly improved. To meet the needs of all kinds of small medium and large transformer test.
Alternative Name: Transformer transformation ratio group tester, transformer transformation ratio tester, transformer transformation ratio full-automatic tester, full-automatic transformer transformation ratio tester, transformer transformation ratio group tester, transformer transformation ratio tester, transformer transformation ratio full-automatic tester
Features
1.Transformer ratio tester can automatically measure wiring group
2.Automatic group transformation
3.Automatic phase sequence switching line group parameters;
4.Fast measuring speed;
5.Automatic range switching
6 Automatic calibration table
7.Once the measurement is completed, automatic cut off the test power;
8.Set data, automatic measurement results, can view the previous data;
9.Test transformer on-load, only need once input ratio;
10.Measure the on load transformer and input the transformation ratio only once
11.Easy to carry, suitable for field operations
Product Parameters
Type | ZC-203A | |
Function | Transformer ratio, group, polarity test | |
Working power | Input voltage | 185Vac~250Vac |
Allowable voltage | 85Vac~264Vac | |
Frequency | 50/60Hz | |
Allowable frequency | 45Hz~65Hz | |
Input power | 40VA | |
Joint | Standard AC socket 60320 | |
Measuring range | Ratio test range | 1~9999.9 |
Group test range | 1~12 | |
Test accuracy | Accuracy | 1~999.99:0.2%;1000~9999.9:0.5% |
Environment condition | Operating temperature | 0℃~+40℃ |
Resolving power | Relative humidity:5%~95%,No dew | |
Accuracy | 0.2%±0.001A | |
Frequency | Range | 45Hz~65Hz |
Resolving power | 0.001Hz | |
Accuracy | 0.2%±0.001Hz | |
Power | Range | 0~39kW |
Resolving power | 0.001kW | |
Accuracy | <±0.5%(CosΦ>0.1),±1.0%(0.02<CosΦ<0.1) | |
Capacity test range | 10kV Dry type transformer | 30kVA~3150kVA |
10kV Oil immersed transformer | 30kVA~31500kVA | |
35kV Oil immersed transformer | 50kVA~31500kVA | |
20kV Dry type transformer | 50kVA~2500kVA | |
35kV Dry type transformer | 50kVA~2000kVA | |
Environment condition | Operating temperature | -10℃~+50℃ |
Storage temperature | -25℃~+70℃ | |
Physical characteristics | Size | 400×290×170mm3 |
Weight | ≈7kg (Do not include attachments) |
OUR SERVICE:
● We will provide more precisely and efficiently manufacture and serve according to clients' requirements.
● We have professional QC team to ensure your product more better.
● Check the raw material before starting production.
● Have the random inspection during the processing.
● Make the 100% inspection before the shipments.
HIGH QUALITY:
Passed the ISO9001:2008 quality system authentication.
FAQ
1. What is the payment term?
T/T, L/C at sight, Western Union, PayPal, etc.
2. What about the leading time for production?
Honestly, it depends on the order quantity and the product. Usually our leading it 7 working days after order confirmed.
3. Could I use my own LOGO or design on goods?
Yes, customized logo are available.
4. Could you please tell me the Warranty period of your products?
Our warranty period is one year free and lifelong maintenance, and if the product we sell is damaged (if not man-made damage), in the first year, we will send free parts for free replacement.
Over the warranty, the maintenance is paid service.
5. Do you have Technical Backup to all customers from different customers?
To be surely, our technical support is always available and quick response.
We are manufacture of so much on site testing experience and understand how to deal with your problems. Moreover, our engineer can go to your country to support if need.