DC High Voltage Generator

DC High Voltage Generator
DC High Voltage Generator

120kv 10ma DC High Voltage Generator

I.Introduction of 120kv 10ma DC High Voltage Generator DC high voltage generator is DC high voltage power supply equipment. It have functions of switch on protection under 0 voltage,over voltage and over current protection. They are high stability and reliability. It is easy to operate , small in size and light in weight. 


II.Main Functional Characteristics of 120kv 10ma DC High Voltage Generator

1、Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use.

2、Full range of linear smoothly adjusted voltage, with voltage regulation accuracy smaller than 0.1%; voltage measurement accuracy is 0.5%, resolution 0.1kv; Current measurement accuracy is 0.5%, the minimum resolution: control box 1µA, shock resistance current 0.1µA.

3、The generator uses AC 220 V power supply (AC220V±10%, 50 hz±1%), the ripple factor is less than 0.5%, and can be used for all-weather at the site .

4、High voltage multiplier uses Dupont materials for full solid encapsulation, overcoming the inconvenience brought by the air and oil filled equipment. Broad base and outer cylinder of light quality makes it stand steadily and more convenient for maintenance.

  5、75% MOA voltage switch button, simple and convenient testing arrester.

6、Over-voltage setting function displays the over-voltage value during regulation process; perfect protection against discharge of over-voltage, over-current and short circuit. This is the best companion for cable experiments.

7、Perfect break line and non-zero potential start protection function protects the operator and samples at any time. This product has overall design of shock-proof control box, concise, clear panel design and voice prompt for operation.


III.Major parameters for 120kv 10ma DC High Voltage Generator  

Model Technical40/2 60/2 60/5 120/2 120/3 120/5 120/10 200/2 200/3 200/5 300/2 300/5
Voltage accuracy Current accuracyDRO ± (1.0% of reading ± 0.2KV) DRO ± (1.0% of reading ± 2)
Ripple factor≤0.5%
Voltage stabilityRandom fluctuations, Supply voltage transformation ratio±10%≤1%
Overload capacityNo-load voltage can exceed 10% of the rated voltage  using ten minutes maximum charging current of  1.5 times the rated current
Power supplySingle-phase current 50HZ 220V±10%
Working styleIntermittent use
A continuous period of up to 30 minutes
Working environmentTemperature: -10~40ºC
Relative Humidity: Room temperature is 25ºC less than 85% (non-condensing)
Altitude: less than 1500m
With a capacitive load capacityTest capacity is unlimited
1.5 times the rated current available to charge
Structural featuresEpoxy fiberglass  electrical Insulation times the pressure cylinder
Air-insulated, no worry of leakage
  Features of Operation BoxHigh Precision 1mA- 0.75UDC  One-touch buttons (Accuracy≤1.0%) Most suitable for MOA test
Overvoltage protection using DIP settings, at a glance
Vertical and Horizontal type of international standard chassis,  the scene is more convenient