Resonant Test System
Variable frequency series high voltage ac resonant test system Introduction
ZCVF-A series frequency conversion series resonant AC withstand voltage device is suitable for AC withstand voltage test of transformer, circuit breaker, switch, GIS system, cable, bushing, insulator and other equipment. It has the functions of high voltage over-voltage protection, low voltage over-current protection, detuning protection, zero position protection, flashover protection, emergency shutdown, under-voltage protection and so on. It not only meets the requirements of equipment test conditions for high voltage and small current, but also meets the requirements of equipment test conditions for low voltage and large current, and has a wide application range.
HV AC Frequency Series Resonant Test Set Features
1. The required power supply capacity is greatly reduced, and the power required for the test is only 1/Q of the test capacity.
2. Small size, light weight, generally 1/3-1/5 of the ordinary test device;
3. The resonant power supply is a resonant filter circuit, which can improve the waveform distortion of output voltage, obtain good
Sinusoidal waveform, and effectively prevent the wrong breakdown of the sample by harmonic peak value.
4. Variable-frequency power supply has strong protection function and good stability. It has automatic (automatic tuning, automati
boosting), full manual (manual tuning, manual boosting) and semi-automatic (automatic tuning, manual boosting and manual tuning,automatic boosting) working modes, which can be switched over and used arbitrarily and operated conveniently. 220V or 380V single-phase power supply is used to facilitate on-site power access.
5. Flexible configuration, strong expansion function. The resonant reactor adopts multi-mode, building block combination, can be series and parallel, which meets the test requirements of a variety of samples and is more convenient for field use.
6. Large screen touch LED LCD color screen and external mouse directly complete the setting of various parameters. The test results can be saved, printed, uploaded, and retrieved and so on.
7. The frequency regulation of ZCVF-A series frequency conversion series resonant AC withstand voltage device can be divided into coarse tuning and fine tuning, and the test resonant point can be automatically found to ensure that the resonant frequency does not drift during the whole test process; the required power supply capacity is small, the power required for the test is only 1/Q of the test capacity the volume is small, the weight is light, and the resonant power supply is 1/3-1/5 of the ordinary test device; the resonant power supply resonant type. The filter circuit can improve the waveform distortion of the output voltage; obtain good sinusoidal waveform, effectively prevent the wrong breakdown of the sample by harmonic peak value; has a variety of working modes, using 220V or 380V single-phase power supply to facilitate on-site power supply; multi-mode, building block combination, can be operated in series and parallel, easy to use in the field.
Product Parameters
Rated output voltage | 0~ 1000kV and below | ||||
Output frequency | 30 ~ 300Hz | ||||
Resonant Voltage Waveform | Pure sine wave, waveform distortion rate≤1.0% | ||||
Working hours | Full Power Continuous Working Time: 60min | ||||
Quality factor | 30~ 90 | ||||
Frequency regulation sensitivity | 0.1Hz | ||||
Instability | < 0.05% | ||||
Working power supply | Single phase 220V or 3 phase 380V+ 10% | ||||
Power frequency 50Hz+5% | |||||
Type | Variable frequency power supply | Resonant reactor | Excitation transformer | Divider | Scope of application |
ZCVF-A-54/54
| 3kW
| 27kV/1A 2sets (dry type)
| 3kVA (dry type)
| 60kV | 1000kVA and below 10kV power transformer 10kV switches and buses、PT CT etc. 10kV (300mm2) cables 1.0km
|
ZCVF-A-108/108
| 5kW
| 27kV/1A 4sets (dry type)
| 5kVA (dry type) | 110kV | 31500kVA and below 35kV power transformer 35kV switches and buses ,PT、CT etc. 10kV (300mm2) cable 2km 35kV (300mm2) cable 0.5km |
ZCVF-A-200/200
| 10kW
| 50kV/1A 4sets (dry type) | 10kVA (dry type)
| 200kV | 50000kVA and below 110kV power transformer 110kVGIS、PT、CT etc. (Preventive test) 35kV (300mm2) cables 1.0km 10kV (300mm2) cables≤2.0k |
ZCVF-A-270/270
| 15kW
| 45kV/1A 6sets (dry type) | 15kVA (dry type)
| 300kV | 50000kVA and below 110kV power transformer 110kVGIS、PT、CT etc. 35kV (300mm2) cable≤ 1.2km 10kV (300mm2) cables≤ 3.0km |
ZCVF- A-800/400
| 30kW
| 50kV/2A 8sets (dry type) 100kV/2A 4sets (oil type) | 30kVA (dry type)
| 400kV | 80000kVA and below 220kV power transformer 50000kVA and below 110kV| power transformer 110kV/220kVGIS、PT、 CT etc. 35kV (300mm2) cable s2.0km 110kV (300mm2) cable ≤0.7km |
ZCVF-A-1600/800
| 60kW
| 200kV/2A 4sets (oil type)
| 60kVA (dry type)
| 800kV | 80000kVA and below 220kV power transformer 50000kVA and below 1 10kV power transformer 500kVGIS、PT、 CT etc. 220kV switches、GIS、 PT、CT ect. 110kV (400mm2) cables 1.5km 220kV (400mm2) cable≤ 1.0km |
Why Choose us?
1. Owning advanced equipment and technology with our own Technology Dept.;
2.Good quality can be ensured by our Professional QC team with competitive price.
State Grid Corporation of China is one of our customer!
3.Certifications are available.
4.OEM Service Offered.
5.Design Service Offered.
6.Small trial order can be accepted to see our quality and service.
7. Standardization, effectiveness and timeliness of the pre-sale, in-sale and after sales service.