Three Phase Power Analyzer
ZC-201A Transformer power analyzer
ZC- 201A transformer power analyzer can measure no-load current, no-load loss, short-circuit voltage and short-circuit (load) loss of transformer. It can carry out harmonic test and analyze to the 31st harmonic. The instrument automatically switches the measuring range inside, allowing a wide range of measuring voltage, current and simple wiring. During the no-load and load test of three-phase transformer, the instrument can automatically judge whether the wiring is correct and display the vector diagram of three-phase voltage and current.
Technical Data
Model | ZC-201A | |
Test purpose | No load current, no load loss, short circuit voltage, short circuit (load), loss measurement of transformer | |
Working power supply | Input voltage | 185Vac ~ 250Vac |
Allowable input voltage | 85Vac ~ 264Vac | |
Frequency | 50 / 60Hz | |
Input power | 40VA | |
Connector | standard DC plug 60320 | |
AC Voltage | Range | 10V ~ 650v |
Resolution ratio | 0.001V | |
Accuracy | 0.1%±0.00V | |
AC Current | Range | 0.01A ~ 5A |
Resolution ratio | 0.001A | |
Accuracy | 0.1%±0.001A | |
Frequency | Range | 45Hz~65Hz |
Resolution Ratio | 0.001Hz | |
Accuracy | 0.2%±0.001Hz | |
Power | Range | 0.3Kw |
Resolution Ratio | 0.001kW | |
Accuracy | <±0.5%(Cosφ>0.1)±1%(0.02<Cos<0.1》) | |
Environment Condition | Storage temperature | - 25° C to +750 ° C |
humidity | Relative humidity: 5% - 95%, no condensation | |
physical characteristics | Size | 360x 220x 150mm3 |
Weight | ≈5KG (Without Accessory) |
Product Features
1. It can measure no-load current, no-load loss, short-circuit voltage and short-circuit (load) loss of transformer.
2. Transformer harmonic test can be carried out.
3. During the no-load and load test of three-phase transformer, the instrument can automatically judge whether the wiring is correct and display the vector diagram of three-phase voltage and current.
4. Single machine can complete the measurement of load test under the full current of distribution transformer below 100kVA; under the third rated current, it can complete the measurement of load test of distribution transformer below 250kVA (under the third rated current, the instrument can be converted to the load loss parameter under the rated current).
5. All test results are automatically corrected. The instrument can automatically carry out a variety of corrections, such as: waveform correction, temperature correction, non-rated voltage correction, non-rated current correction, etc., so that the accuracy of the test results is higher.
6. The instrument can preset 40 groups of test object parameters by users, and these parameters can be deleted and added at any time according to needs, which is very convenient to use.
7. It has a real-time electronic clock, which can automatically record the date and time of the test, which is conducive to the storage and management of the test results.
8. Panel thermal printer. The test results can be printed quickly on site.
OUR SERVICE:
● We will provide more precisely and efficiently manufacture and serve according to clients' requirements.
● We have professional QC team to ensure your product more better.
● Check the raw material before starting production.
● Have the random inspection during the processing.
● Make the 100% inspection before the shipments.
HIGH QUALITY:
Passed the ISO9001:2008 quality system authentication.