CT PT Comprehensive Analyzer

CT PT Comprehensive Analyzer
CT PT Comprehensive Analyzer

Intelligent CT PT Analyzer introduction

image001

It automatically determines all relevant current transformer values and compares the results with the selected standard. The device allows all types of single and multi-ratio current transformers to be tested, and evaluates the current transformer as per the IEC or IEEE standard within seconds with the push of a button.

Alternative name: CT parameter analyzer, CT analyzer, variable frequency CT analyzer, ctpt analyzer, transformer characteristic tester, variable frequency transformer characteristic tester,

CT PT Analyzer Parameters

Model

CTA-1000C

Test purpose

CT: Test requirements for excitation characteristics, transformation ratio, polarity, secondary winding resistance, secondary load, ratio difference and angle difference PT: Test requirements for excitation characteristics, transformation ratio, polarity, secondary winding resistance, etc

Working power supply

Input voltage

185Vac ~ 250Vac

Allowed Input voltage

80Vac~264Vac

Frequency

50 / 60Hz

Allowed input voltage

45~65Hz

Input power

800VA

Connector

standard AC plug 60320

CT ratio accuracy

Transformation ratio1~2000

0.02%(typical value)/ 0.05%(guaranteed value)

Transformation ratio2000~5000

0.03%(typical value)/ 0.1%(guaranteed value)

Transformation ratio5000~40000

0.05%(typical value)/0.2 %(guaranteed value)

PT ratio accuracy

Transformation ratio1~2000

0.02%(typical value)/ 0.05%(guaranteed value)

Transformation ratio2000~5000

0.03%(typical value)/ 0.1%(guaranteed value)

Transformation ratio5000~40000

0.05%(typical value)/0.2 %(guaranteed value)

Phase measurement

resolution

0.01min

Accuracy

1min(typical value)/3(guaranteed value)

Secondary winding resistance measurement

range

0Ω ~ 300Ω

resolution

Accuracy

0.05%(typical value)/0.1%+1Ω(guaranteed value)

AC load measurement

range

0VA~ 1000VA

resolution

0.01VA

Accuracy

0.05%(typical value)/0.1%+0.01VA(guaranteed value)

Output

Output Voltage

0Vac~180Vac

Output current

0Aeff~12Aeff(36Apeak)

Output Power

0VAeff~800VAeff(1800VApeak)

environment condition

Operating temperature

- 10 ° C to + 50 ° C

Storage temperature

- 25 ° C to + 70 ° C

humidity

Relative humidity:5%~95%,no condensation

Weight and Dimensions

Size

360x285x145mm3

Weight

≈8kg (Without accessories)

Product core characteristics

image003

01. the interface is friendly and with pretty sight

Ultra-large LCD display is novel in design convenient and simple to operate.

02. Fan with Good heat radiation

Sleek edges without burrs, neat

Appearance and generous appearance.

image005
image007

03. Safety protection of instrument outer box

The enclosed space ensures the safety of the equipment and easy to carry

04. Clear and intuitive output socket

Flexible wiring,

Multiple selectivity,

Easy and convenient.

image009



CT PT Comprehensive Analyzer